Rainer Luetzkendorf
|
Thursday 03 April 2008 3:18:01 pm DC of a 1oo2D-system
Hello |
|
Michel Houtermans |
Saturday 26 April 2008 10:12:19 am Re: DC of a 1oo2D-system
You make an FMEDA of the channel and when you introduce the failure modes you take into account whether the channel on its own can detect via diagnostics the failure or whether it can only be detected when you have the second channel and they communicate somehow. |